Loading...
FA465926QZ019
Response Deadline
Aug 14, 2026, 6:00 PM(CDT)7 days
Eligibility
Contract Type
Sources Sought
Sources Sought: SAM Notice ID FA465926QZ019
COMPUTER ROOM AIR CONDITIONER (CRAC) REPLACEMENT at GRAND FORKS AFB, ND
THIS IS NOT A SOLICITATION!
This notice does not constitute a commitment by the Government. All information submitted in response to this announcement is voluntary and the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government.
This notice also serves to gain information and estimates on both purchasing the units with a four-year maintenance plan vs. renting with a four-year maintenance plan. Please provide two separate estimates in your response.
There is a need for Computer Room Air Conditioner (CRAC unit) at Grand Forks Air Force Base, ND. The requirement includes contractors removing and disposing of the current CRAC unit. They shall safely decommission, disconnect, and dispose of the existing legacy CRAC unit, associated pumps, and the existing dry cooler. All equipment, piping, fluid solutions, and debris shall become the property of the contractor. The contractor is responsible for the safe and proper transport and legal disposal of all materials off base, in strict accordance with local, state, and federal environmental regulations. The contractor will procure and install a dual CRAC unit system.
CRAC Units: Provide and install two (2) 8-Ton CRAC units. Both units must feature multi-stage cooling capabilities.
1. System must be capable of maintaining MCE internal temperature at 60 to 70 degrees Fahrenheit.
2. System must include integrated humidification and de-humidification capabilities designed to continuously maintain a relative humidity (RH) of 40% to 50%.
3. The systems shall operate using a solution comprised of 40% inhibited propylene glycol and 60% Reverse Osmosis (R.O.) water.
4. Each CRAC unit shall be equipped with separate, autonomous control systems, ensuring both units can operate fully independent of one another.
The contractor shall provide and install new dry coolers for each independent system. Dry coolers must be appropriately sized to support free-cooling operations. They shall also provide and install new, redundant pumps for each CRAC system. All pumps must be sized in strict accordance with the equipment manufacturer's requirements. New piping must be provided and installed for both systems, sized according to the manufacturer's specifications. The contractor shall provide and install movable ductwork designed to allow the backup CRAC unit to be quickly and efficiently connected to the MCE. They will provide O&M manuals and train 319 AMXS personnel on preventative maintenance, start/stop, and failover procedures. Lastly, they will conduct preventative maintenance based on equipment manufactures instructions and provide 24/7 emergency repair services for 4 years post acceptance.
All other information pertaining to this requirement can be found in the DRAFT PWS attached to this RFI.
The result of this market research will contribute to determining the method of procurement.
The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 238220 - Plumbing, Heating, and Air-Conditioning Contractors
NOTE: If you believe the above NAICS to be incorrect please suggest alternate NAICS for this acquisition.
If your organization is willing and capable of providing the above-mentioned government needs, please respond with the following information:
Organization Name:
SAM UEI:
CAGE Code:
Business Type (Include all applicable designations):
Small Business Under NAICS – 238220? (Y/N):
POC Telephone Number:
POC Email:
Projected Delivery Date (XX number of days after award):
If you have an existing Government contract vehicle (GSA, NASA SEWP, NIH NITAAC etc.) that can provide this requirement, please provide the contract number:
All interested firms should submit a capabilities package that outlines the firm’s ability to supply the requirements mentioned above. The capabilities package should be brief and concise yet clearly demonstrate the ability to meet the stated specifications and quantities. If teaming or subcontracting arrangements are anticipated, these should be clearly identified. The response must not exceed 5 pages.
WE ARE PRIMARILY SEEKING RESPONSES FROM SMALL BUSINESSES REGISTERED UNDER THE AFOREMENTIONED NAICS CODE; HOWEVER, ALL WILLING AND CAPABLE VENDORS ARE ENCOURAGED TO SUBMIT THEIR RESPONSE.
Submit all responses via email to SSgt Ellod Richardson at ellod.richardson@us.af.mil and SSgt Jhala N. Neupane at jhala.neupane@us.af.mil and TSgt Trenton Cott at trenton.cott@us.af.mil no later than 14 AUGUST 2026, 1:00 PM CST.
DEPT OF DEFENSE
DEPT OF THE AIR FORCE
AIR COMBAT COMMAND
FA4659 319 CONS PK
FA4659 319 CONS PK
ADMIN ONLY NO REQTN CP 701 747 5252
295 STEEN BLVD BLDG 242
GRAND FORKS AFB, ND, 58205
NAICS
Plumbing, Heating, and Air-Conditioning Contractors
PSC
REFRIGERATION AND AIR CONDITIONING COMPONENTS
Set-Aside
No Set aside used