Loading...
SPMYM126Q4059
Response Deadline
May 4, 2026, 4:00 PM(EDT)6 days
Eligibility
Contract Type
Combined Synopsis/Solicitation
This is a COMBINED SYNOPSIS/SOLICITATION for commercial items prepared in accordance with the information in Federal Acquisition Regulation (FAR) Part 13 using Simplified Acquisition Procedures (SAP). This announcement constitutes the only solicitation; a written solicitation will not be issued. PAPER COPIES OF THIS SOLICITATION WILL NOT BE AVAILABLE. This combined synopsis/solicitation WILL be posted to SAM at https://sam.gov.
SOLICITATION NUMBER: SPMYM126Q4059
BUYER: RONALD MARTIN
EMAIL ADDRESS: ronald.c.martin@dla.mil
This solicitation documents and incorporates provisions and clauses in effect though FAC 2025-05 and the DFARS Change notice 08/07/2025. It is the responsibility of the contractor to be familiar with the applicable clauses and provisions. The clauses may be accessed in full text at this website: https://www.acquisition.gov/.
NNSY - Norfolk Naval Shipyard requests responses from qualified sources capable of providing the material that is referenced below. All items shall be new. No refurbished or used items will be accepted. This solicitation is BRAND NAME only, 100% small business set-aside utilizing Lowest Price Technically Acceptable evaluation factors.
CLIN NUMBER DESCRIPTION QTY UNIT PRICE TOTAL
CLIN 0001
60438640 UPS MODULE, 250KVA, W/ INTERNAL BYPASS, TOP/BTM 1 ENTRY
ONLINE TRUE DOUBLE CONVERSION.
Manufacturer: AGSI Systems LLC 1 EA
CLIN 0002
60438641 TRANSFORMER CABINET
3- PHASE 480V DEL TA - 208 Y120
Manufacturer: AGSI Systems LLC 1EA
CLIN 0003
60438642 BATTERY CABINET (1) STRING 390W, 400A BREAKER
Manufacturer: AGSI Systems LLC 4 EA
CLIN 0001 SPECIFICATIONS:
UPS MODULE, 250kva, w/ internal bypass
-Top/btm 1 entry online true double conversion.
- Advanced circuitry to prevent unexpected failure.
- PWM INVERTER utilizing insulated gate bipolar transistor.
- PARALLEL UP TO 8 MODULES for capacity or redundancy in single model and group module configurations with optional parallel kit.
- Regulated output voltage +/- 1% with balanced load, +/- 3% with 100% unbalanced load.
- Menu driven front panel display with sub-menu selections that give complete access to all modes of operation and critical alarm conditions.
- Battery cycle monitoring: advanced battery protection and self-test diagnostics that provide the highest level of protection against overheating, deep discharge and low current. Provides detailed BATTERY INFORMATION such as hours of normal operation, hours on bypass, time on battery, number of partial and full discharges for battery warranty validation.
- Internal input isolation switch, output isolation switch and system bypass isolation switch.
- Automatic continuous duty static bypass.
- Remote monitoring with RS 232 serial port and programmable form C dry contacts.
- HIGH AC TO AC Efficiency 2 YEAR Full warranty Included
REMOVAL-DISPOSAL (NO EXISTING ELECTRICAL-ENVIRONMENT ISSUES)
labor and start up included 1 on-site 5 x 8 startup. Startup performed after installation by owner. This includes installation inspection, check-out and activation of
THE UPS, instruction of operational personnel and warranty validation. Does not include load bank testing & burn in.
Start-up service as included provided.
Start-up required for on-site warranty validation.
DEPT OF DEFENSE
DEFENSE LOGISTICS AGENCY
DLA MARITIME
DLA MARITIME SHIPYARDS
DLA MARITIME - NORFOLK
DLA MARITIME - NORFOLK
CONTRACTING DIVISION (DLA-NMAB)
PORTSMOUTH, VA, 23709-5000
NAICS
Other Computer Related Services
PSC
IT AND TELECOM - OTHER DATA CENTER FACILITIES PRODUCTS (HARDWARE AND PERPETUAL LICENSE SOFTWARE)