This solicitation, W50S72-26-Q-7114, is being issued as a Request for Quotation (RFQ). This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2026-01, effective 13 March 2026. The Government intends to award a firm-fixed price (FFP) contract to the vendor whose quote is the lowest price that meets or exceeds the minimum specifications. This procurement is set aside 100% for small business. The NAICS code applicable to this requirement is 333912 and the small business size standard is 1,000 employees. The Government intends to make a single award as a result of this solicitation; however, multiple awards may be made if determined to be in the Government's best interest. The following commercial items are requested in this solicitation:
Required Line Items:
-Industrial, 25 horsepower, two-stage electric-powered reciprocating air compressor with a 120 gallon horizontal tank and an integrated aftercooler. Will be powered by current electrical capability of 480 volt, 3 phase, 40 amps. Must be compatible with existing Ingersoll-Rand air dryer (Model DA170EC), not currently connected. Must have a minimum output pressure of 175 PSI. A CFM output can be between 80 – 100 CFM. Can be mounted a 4 inch raised concrete slab measuring 43 inches deep X 72 inches wide. There is 24 inches of available space in front of slab along the 72 inch wide section.
-Install newly procured air compressor in the same location as the replaced compressor. Make all necessary adjustments to connect new compressor to existing air supply lines, electrical connections, and the existing air dryer. Ensure air compressor and air dryer operate and function properly after insulation.
-Remove and dispose of currently installed air compressor (Ingersoll-Rand, Model 13025120H), from Bldg. 252 (A.G.E. Building). Door access opening is 60 inches wide and 84 inches tall. Compressor is located on the ground floor.
***PHOTOS ATTACHED OF CURRENT COMPRESSOR AND LOCATION IN WHICH NEW COMPRESSOR WILL NEED TO BE PLACED
SUBMISSION REQUIREMENTS/RFQ TERMS:
1. Offerors shall submit ALL of the following information with their quote on attached vendor information sheet.
2. Offerors quotes shall include adequate information (product brochures, cut sheets, technical data sheets, etc.) for the Government to determine if the item being offered meets the Minimum Specifications identified below. Links to web sites are not acceptable. Failure to provide adequate specification information will render the quote non-responsive, and it will not be considered for award.
3. FAR and DFARS provisions/clauses incorporated into this RFQ and/or the resulting contract(s) are attached in full text provisions and clauses attachment. The full text of the referenced provisions/clauses may be found at http://www.acquisition.gov. Vendors must submit the Representations and Certifications from, Full Text Provisions and Clauses, with their quote only if they differ from, or have not been completed within, their System for Award Management (SAM) profile. Failure to provide representations and certifications form, or have them completed within SAM profile will render the quote non-responsive, and it will not be considered for award.
4. Contractors must have an active System for Award Management (SAM) registration to be eligible for award. Register or check the status of your registration at http://www.sam.gov. Please ensure your SAM profile reflects all socio-economic group(s) and NAICS Codes applicable to your business. If the NAICS code listed above is not included in your SAM profile, you must also complete the representations in FAR 52.219-1 and attach it to your quote. Contractors must submit invoices electronically using the Invoicing, Receipt, Acceptance, and Property Transfer (iRAPT) application within Wide Area Work Flow (WAWF) at https://wawf.eb.mil, and receive payment via Electronic Funds Transfer (EFT) to the bank account listed in their SAM profile. Please verify with your accounts receivable/billing department that they can comply with this billing method prior to submitting a quotation.
5. A small business joint venture offeror must submit, with its offer, the representation required in paragraph (c) of FAR solicitation provision 52.212-3, Offeror Representations and Certifications-Commercial Products and Commercial Services, and paragraph (c) of FAR solicitation provision 52.219-1, Small Business Program Representations, in accordance with 52.204-8(d) and 52.212-3(b) for the following categories:
(A) Small business;
(B) Service-disabled veteran-owned small business;
(C) Women-owned small business (WOSB) under the WOSB Program;
(D) Economically disadvantaged women-owned small business under the WOSB Program; or
(E) Historically underutilized business zone small business.
6. Questions regarding this solicitation shall be emailed to SMSgt. Mark Crombie, no later than 10:30 A.M. Central on Thursday, 10 September 2026. Questions and Answers will be consolidated into a single Q&A document on a non-attribution basis and posted to the solicitation.
7. Proposals are due at: Tuesday, 15 September 2026 at 10:30 A.M. Central -
185ARW/MSC
ATTN: SMSgt. Mark A. Crombie
2920 Headquarters Avenue
Sioux City, IA 51111-1300.
Proposals may be submitted by mail, hand delivered, or e-mail to mark.crombie.1@us.af.mil.
It is the vendor's responsibility to verify that quotes have been received at the Contracting Office prior to the due date and time.
DEPT OF DEFENSE
DEPT OF THE ARMY
NATIONAL GUARD BUREAU
JFHQ USPFO IA
USPFO IA PROCUREMENT
W7M8 USPFO ACTIVITY IAANG 185
W7M8 USPFO ACTIVITY IAANG 185
KO FOR IAANG DO NOT DELETE
2920 HEADQUARTERS AVE
SIOUX CITY, IA, 51111-1396
NAICS
Air and Gas Compressor Manufacturing
PSC
COMPRESSORS AND VACUUM PUMPS
Set-Aside
Total Small Business Set-Aside (FAR 19.5)